Programming the linearizer – AW Gear Meters EMO-1005 User Manual

Page 29

Advertising
background image

AW-Lake Company 8809 Industrial Drive, Franksville, WI 53126  web: www.awgearmeters.com

 Tel: 262-884-9800  Fax: 262-884-9810  Email: [email protected]

REV. 1a 05/98 EMO-1005 Manual.DOC

28

PROGRAMMING THE LINEARIZER

To enter the Linearizer mode press the following key sequence:

CHA

->

DP

->

ENT

->

DP

Now the display shows:

LINEARIZER !!!

1=CL 2=AC 3=DEAC

By pressing the 1 key the Linearizer will be cleared. This means all error values are set to +12.7% and

all frequency points are set to zero.

By pressing the 2 key the Linearizer will be activated.

By pressing the 3 key the Linearizer will de deactivated.

Regardless of the key pressed the following display will come up:

LINEARIZER PROG?

0 = NO AND 1 = YES

If the 0 key is pressed the Linearizer selection done above will go into effect and the unit returns to the

regular operating screen.

If the 1 key is pressed the unit enters a 10-point programming routine. When the 10-point programming

routine is entered there is no short cut, which means, all of the errors and points have to be reviewed

and entered.

The following display will appear:

ERRxx=00000yy.y%

POIxx=zzzzz.zzHz

where,

xx is the current point 01 through 10

yy.y is the error -12.7% to +12.7% at point xx

zzzzz.zz is the frequency at which the error xx occurs.

There are 10 points to be programmed. The first thing to be entered is the percentage of error. To

change the sign use the DP key. After the correct percentage of error is put in the unit and the correct

sign is selected (+ or -) then press the ENT key. On the second line is the frequency at which the above

error occurs. Enter new frequency and press the ENT key. All ten points will show up, but only

program the points that are necessary. Leave all unused points at zero Hz.

The Linearizer uses linear interpolation between points, which means a straight line between two error

points.

** IMPORTANT ** The channel that will be linearized is the one on the display line 1 !!!!!

Advertising