CHANNEL MODE SELECTION

Each channel card installed in an EMO-1005 is a separate microprocessor controlled system. Each
channel card has the option to designated as a Monitor, PI Controller, Closed Loop Controller
(CLC) or a Complex Ratio System
. To change a channel card to a different mode press the following
key sequence:


CHA

->

DP

->

ENT -> LIM


When this is done the following screen will appear:



MODE: 1=MON 2=PID
3=GON 4=TRA 5=RA



The next five sections will explain what happens when these numbers are selected.

For standard PID operations, select Mode #4, TRANSPARENT - This replaces Mode #2 for all
uses.


MONITOR MODE (Select 1)


When a 1 is selected in the above screen, the channel card will be designated as a Monitor card. In the
standard monitor mode the EMO-1005 will read the incoming frequency, display the derived rate and
total on the display, and adjust the Analog Outputs and Limits accordingly.


Using the 2 line display, both Rate and Total or Rate from 2 different channels could be
monitored simultaneously - or any combinations of Rate, Total and Peak Rate.