EMO‐3000

 

Operation and Programming Manual 

 

 

 

15 

      
 

Limit Operations 

You can set up the EMO‐3000 for 4 Limit Outputs by changing the factory‐set opto‐coupler arrangement 
from the PID settings of 3 inputs and 1 output to the Monitor Mode settings of 4 outputs. You can 
program any opto‐coupler set for an Output to react to the following functions according to the LIMIT 
RULE programmed. See page 27. 

Limit Rule 

Function 

11 

Total Limit for A input 

12 

Rate  Limit for A input 

13 

Ratio Limit for A input 

21 

Total Limit for B input 

22 

Rate  Limit for B input 

23 

Ratio Limit for B input 

 

If any of the above is selected to trigger a Limit, the next step is to program the Trip Point. This is done 
under the LIMIT VARIABLES section (see page 26).  Choices are: 

Total Limit 1 =   

XXXXX. 

Total Limit 2 =   

XXXXX. 

Total Limit 3 =   

XXXXX. 

Total Limit 4 =   

XXXXX. 

 

Flow Limit  1 =   

XXXX.X 

Flow Margin 1 =  

XXXX.X 

Flow Limit  2 =   

XXXX.X 

Flow Margin 2 =   

XXXX.X 

Flow Limit  3 =   

XXXX.X 

Flow Margin 3 =  

XXXX.X 

Flow Limit  4 =   

XXXX.X 

Flow Margin 4 =  

XXXX.X 

 