F3 = RATIO DISPLAY 

Use F3 on the Main Menu to select the Ratio Display Screen. This operation screen shows both the rates 
from frequency inputs A and B, and the Ratio A/B. 

RATIO DISPLAY 

 

 

FOR CHANNEL  XX 

 
RATE  A= 

 

XXX.X ccm 

 

RATE  B= 

 

XXX.X ccm 

 

 

 

 

RATIO A/B=    

XXX.XX 

 

SET RATIO=    

XX.XX 

 

F1=ESC 

F2=CHNL UP 

F3=CHNL DN

 

 

 

 F2 pages UP through the channels. 
 F3 pages DOWN through the channels. 

To show multiple channel displays of ratio, refer to the ACTION RATIO section from the MAIN MENU.  

Programming with the DM‐3000 

F4 = PROGRAMMING 

Selecting Programming from the Main Menu calls up the screen below. 

******** PROGRAMMING   MENU ***************** 

F1= MAIN MENU  (ESC) 

F2= GENERAL A 

F3= PID VARIABLES 

F4= GENERAL B 

F5= ANALOG VARIAB. 

F6= LIMIT VAR. 

    1= LIMIT RULES 

   2= RATIOS            

    3= LINEARIZER 

   4= SPECIAL REPEAT    

     CHANNEL CURRENTLY SELECTED IS XX 
select  one  of the above ...................   
 

In the following sections, you will find instructions about the above areas so you can  access and 
program the desired variable. However, this part of the manual does describe the effect of each variable 
in the EMO‐3000 system. See pages 34 through 45 for detailed information in that regard.  You will most 
likely develop a general knowledge of the EMO‐3000 from the various programming screens in the DM‐