EMO‐3000

 

Operation and Programming Manual 

 

 

 

      
 

Principle of Operation (Example: Paint Application) 

A PLC transmits 

flow instructions to 

the EMO‐3000. The EMO‐3000 then uses an I/P converter and 

pneumatic pressure to control the fluid regulator. The meter measures the flow to the paint nozzle. The 
EMO‐3000 compares this value to the set‐value and makes any adjustments required.   

The device’s internal memory retains flow values from earlier cycles and continuously modifies them as 
new conditions occur. The EMO‐3000 builds adaptive data tables for up to 30 fluids or colors, ensuring a 
fast, highly precise response for a wide variety of fluids and conditions. 

Hardware  

The EMO‐3000’s power supply and channel cards neatly integrate into a durable, efficient, and 
convenient anodized‐aluminum housing compatible with EURO module plug‐in types. The unit is 
expandable to a maximum of 12 channels, in 4‐channel increments. Each interlocking section has its 
own independent power supply.   

The EMO‐3000’s power supply uses plug‐in type fuse holders, which allow for easy replacement without 
having to remove the entire power supply card. Three LEDs indicate whether the AC, positive, and 
negative legs are supplying the channel cards (refer to Appendix I).  An anodized aluminum strip secures 
the cards to the housing. On one end of this strip, the screw terminal slot secures the card in place. At 
the other end, a 90‐degree bend helps with removal or insertion of the card. The watchdog chip 
monitors the microprocessor activity and issues a reset after a 1.6 second delay. Each channel card also 
has a red LED that blinks when the microprocessor is running, and blinks faster when a frequency input 
is applied to the channel.  

EMO‐3000 units manufactured after July, 1993 have RS‐232 and 4‐wire RS‐485 serial communication 
protocol. The RS‐485 serial communication is backward compatible to the previously used 4‐wire RS‐
422.  As an option, these communications ports can be optically insulated from the rest of the EMO‐
3000. The RS‐232 to the (optional) DM‐3000 display is not optically insulated. 

Features 

 Standard unit will hold four channels, expandable to 12 channels 
 Program each channel as a flow monitor or as a closed loop controller 
 Program four alarm limits for each channel to indicate rate, total, or ratio conditions 
 Choose and display over 30 different engineering units 
 Self‐teaching memory retains previous values 
 I/O interface allows for remote data collection, programming, and PLC interface 
 Multi‐unit interfacing 

Technical Data

 

 Ratio: flow A, flow B, or flow A/B 