Caution – HT instruments HT8000 User Manual

Page 10

Advertising
background image

HT8000

EN - 9

4.3.3. DC current measurement

CAUTION

Maximum input for DC current is 24mA. Do not attempt to take any current
measurement exceeding such limit to avoid the risk of electrical shock and
damages to the instrument

Fig. 4: DC current measurement


1. Switch OFF the circuit under test
2. Press INPUT/OUTPUT key and select the measurement mode. The “INPUT” symbol is

displayed

3. Press mA/% key and select the desired measurement unit. The symbol “mA” or “mA%”

is displayed

4. Insert the red plug into mA jack and the black plug into COM jack
5. Connect red and black plugs in series with the circuit under test respecting the polarity

and current flow (see Fig. 4).

6. Power the circuit under test. The current value will be displayed
7. The message "O.L" means that the current exceeds the measuring limits. The symbol

"-O.L" on the display means that current has opposite direction than shown in Fig. 4


Advertising