Table 1-2. ate-dmg series specifications, Ate-dmg d-c output ratings and output impedance -2, Ate-dmg series specifications -2 – KEPCO ATE-DMG SERIES User Manual

Page 16

Advertising
background image

1-2

ATE-DMG OPER 042314

addition, output voltage and current can also be controlled by external analog reference volt-
ages (see PAR. 3.5).

TABLE 1-1. ATE-DMG D-C OUTPUT RATINGS AND OUTPUT IMPEDANCE

MODEL

d-c OUTPUT RANGE

OUTPUT IMPEDANCE VOLTAGE MODE

OUPUT IMPEDANCE CURRENT MODE

VOLTS

AMPS

SERIES R

SERIES L

(1)

SHUNTR

(2)

SHUNT C

(3)

SLOW

FAST

SLOW

FAST

SIZE “E” FULL-RACK (1000 Watt)

ATE 6-100DMG

0-6

0-100

1.2



0.5

H

5

H

12k

22000

F

15

F

ATE 15-50DMG

0-15

0-50

6



0.5

H

5

H

30k

12000

F

6

F

ATE 25-40DMG

0-25

0-40

12.5



1

H

10

H

50k

11000

F

4

F

ATE 36-30DMG

0-36

0-30

24



1

H

10

H

72k

9500

F

3

F

ATE 55-20DMG

0-55

0-20

55



2

H

20

H

110k

5200

F

2.25

F

ATE 75-15DMG

0-75

0-15

0.1m

2

H

20

H

150k

3400

F

1.5

F

ATE 100-10DMG

0-100

0-10

0.2m

4

H

40

H

200k

1200

F

0.75

F

ATE 150-7DMG

0-150

0-7

0.42m

4

H

40

H

300k

1050

F

0.3

F

(1)

For determining dynamic impedance in voltage mode.

(2)

Based on 0.5mA load effect in FAST mode.

(3)

For determining dynamic impedance in current mode.

TABLE 1-2. ATE-DMG SERIES SPECIFICATIONS

SPECIFICATION

RATING/DESCRIPTION

CONDITION

INPUT CHARACTERISTICS

A-C Voltage

nominal: 104, 115, 208, 230Va-c

User selectable, See PAR. 2.3

Tolerance: ± 8.7%

Frequency

nominal: 50, 60 Hz

Tolerance: ± 3Hz

Current

20A a-c maximum

Max load, 125V a-c

OUTPUT CHARACTERISTICS

d-c Output

Series Pass Transistor

Type of Stabilizer

Automatic crossover

Voltage/Current

Voltage

0 to 100% of rating

Current

0 to +55

o

C 0-100% of rating

Usable range limited to approximately 1% to 100%.

+55 to +65

o

C 0-90% of rating

Static Specifications

See Table 1-5

Dynamic Specifications

See Table 1-3

Error sense

0.5V per load wire (0.25V for 6V
model)

Voltage allowance

Isolation Voltage

500V d-c or peak

Between each output terminal and chassis ground

Leakage current Output to Ground

5 microamperes max.

rms at 115V a-c

50 microamperes max.

p-p at 115V a-c

Software Overvoltage
Protection (OVP)

See Table 1-4 and PAR. 3.4.3.

Digital setting, local or remote.
Action: crowbar the output.

Advertising