2 turning the power supply on, Turning the power supply on -10 – KEPCO ATE-DMG SERIES User Manual

Page 44

Advertising
background image

3-10

ATE-DMG 042314

3.4.2

TURNING THE POWER SUPPLY ON

Pressing the upper half ( | ) of the POWER switch turns the power supply on; pressing the lower
half of the switch ( O ) shuts the power supply off. When the power supply is turned on, the LCD
first shows the power supply type, e.g., Kepco ATE25-40 GPIB addr. = nn, where nn is the
GPIB address (factory default GPIB address = 6).The LCD then shows the power on defaults
(see Figure 3-6). The defaults are: output enabled, voltage mode, output voltage set to zero,
output current set to a minimum value (1-2% of I

O

max). Power on defaults also include setting

maximum values for overcurrent and overvoltage protection indicated in Table 1-4.

TIME

5

Command Entry

Press to edit time value for specific memory location. Select memory loca-
tion (data entry), then enter time value, 0.01 to 2.5 seconds (data entry).

Data Entry

Press to enter number 5.

3.4.1.2

RUN

6

Command Entry

Press to run a program. Requires data entry to select starting location.
Press ENTER to accept displayed value.

3.4.15.2

Data Entry

Press to enter number 6.

3.4.1.2

RECALL

Command Entry

Press to recall previously stored values of output voltage and current, and
overvoltage and overcurrent protection. Data entry required to select mem-
ory location containing values to be recalled; press ENTER to accept dis-
played value.

3.4.13

CLEAR

Data Entry

Press to exit Data Entry status; any numbers entered are lost. Restores
Command Entry status

3.4.8

1

Data Entry

Press to enter number 1.

3.4.1.2

2

Data Entry

Press to enter number 2.

3.4.1.2

3

Data Entry

Press to enter number 3.

3.4.1.2

ENTER

Data Entry

Press to accept data entered and return to Command Entry status.

3.4.8

Command Entry

— In CV (constant voltage), press to decrease output voltage by increment
equal to voltage resolution (

.0.025% of EOmax).

— In CC (constant current), press to decrease output current by increment
equal to current resolution (

.0.025% of IOmax).

— In EDIT PROG status, changes the parameter displayed on LCD for a
specific memory location and decrements memory location displayed on
LCD.

3.4.8,

Data Entry

Erases number to left, or decreases value shown (e.g. Display Contrast set-
ting).

3.4.8

0

Data Entry

Press to enter number 0.

3.4.1.2

( . )

Data Entry

Press to enter decimal point

3.4.1.2

Command Entry

— In CV (constant voltage), press to increase output voltage by increment
equal to voltage resolution (

.0.025% of EOmax).

— In CC (constant current), press to increase output current by increment
equal to current resolution (

.0.025% of IOmax).

— In EDIT PROG status, changes the parameter displayed on LCD for a
specific memory location and increments memory location displayed on
LCD

3.4.8,

Data Entry

Not used.

TABLE 3-1. KEY FUNCTIONS (CONTINUED)

KEY

POWER SUPPLY

STATUS ACTIVE

DESCRIPTION

REFERENCE

PARAGRAPH

Advertising