B-21/(b-22 blank), Table b-4. error messages (continued) – KEPCO BHK-MG 40W (Half Rack) Series User Manual

Page 147

Advertising
background image

BHK-MG 1/2 (OPR) 121313

B-21/(B-22 Blank)

-282,”Illegal program
name”

Execution error bit 4

Executing prog:run without LIST:SEQ command

-301,”Value bigger than
limit”

Device Error bit 3

(1)

Requesting a time of 656 which is bigger than limit

-311,”Memory error”

Device Error bit 3

(1)

Power-up NV RAM error

-314,”Save/recall
memory error”

Device Error bit 3

(1)

Using cell other than 1 - 41 for SAV and RCL

-341,”Non Volatile
Mem. CRC error”

Device Error bit 3

(1)

Power supply constants may be corrupted; recalibration may be neces-
sary.

-350,Queue overflow

Device Error bit 3

(1)

More than 15 errors are in queue.

-410,”Query
interrupted

Query Error bit 2

New command sent before data from previous query read. Previous
query data lost.

-430,Query Deadlocked

Query Error bit 2

Over 255 characters received in single input string.

(1)

The Device error bit may be set when the status monitoring functions of the power supply detect an overvoltage/undervolt-

age condition.

TABLE B-4. ERROR MESSAGES (CONTINUED)

ERROR MESSAGE

ESR ERROR BIT SET

(SEE PAR. A.5)

EXPLANATION

Advertising