KEPCO BHK-MG 40W (Half Rack) Series User Manual

Page 21

Advertising
background image

BHK-1/2-MG (OPR) 121313

1-5

OUTPUT CHARACTERISTICS (CONTINUED)

Series Connection

Automatic or Master-Slave
Operation, limited by the d-c
isolation limit voltage

For slave unit, use analog programming
only.

Parallel Connection

Automatic or Master-Slave
Operation

For slave unit, use analog programming
only.

GENERAL (ENVIRONMENTAL) CHARACTERISTICS

Temperature

Operating

0° to +50° C

Storage

-20° to +70° C

Humidity

0 to 95% RH

Non condensing

operating & storage

Shock

20g, 11msec ±50%

half sine

Non operating, 3-axes,

3 shocks each axis

Vibration

5-10Hz 10mm

double amplitude

Non operating, 3-axes,

1 hour each axis

Cooling

Built-in fan, exhaust to rear

PHYSICAL CHARACTERISTICS

Dimensions

See Figure 1-2.

Weight

English 26 lbs.

Unpacked

Metric 12 Kg

a-c source connections

Front Circuit Breaker, 2-pole

Rear Detachable IEC 3-wire type

connector

d-c output terminals

Rear panel Terminal Block (11 posi-

tions),

±Output, ±Sense, Ground, Internal
Capacitor (–), Grounding Network

Front panel Jacks (2)

±Output

Control

Local: Digital control using front panel keypad(24 pads) and LCD

Remote: Digital control using rear panel IEEE 488 Bus (24 pin female connector).

Analog control using two rear panel terminal strips (10 positions) for
voltage and current

Digital display
front panel

Voltage, current, mode, set-
tings, menu, program, etc.

2 x 16 character alphanumeric LCD with
LED backlight

TABLE 1-2. BHK-MG 40W SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION