KEPCO BHK-MG 40W (Half Rack) Series User Manual

Page 19

Advertising
background image

BHK-1/2-MG (OPR) 121313

1-3

OUTPUT CHARACTERISTICS (CONTINUED)

Load effect

Voltage 0.005% E

O

max

no load - full load

Current 0.015% I

O

max

short - full load

Temperature effect
(per degree C)

Voltage 0.01% E

O

max

Ambient temperature
0 to 50° C

Current 0.02% I

O

max

Time effect

Voltage 0.01% E

O

max

0.5-8.5 hours
Ambient temperature: 25° C

Current 0.02% I

O

max

Ripple (rms/p-p)
(Slow Mode)

Voltage: 0.004% / 0.04% E

O

max

Minus output terminal connected to GND.

Voltage: Nominal load
Current: Short with calibrated shunt.

Current: 0.02% / 0.2% I

O

max

Programming
rise time (R)/fall time (F)

Voltage Fast

Mode:

Slow Mode:

180

µ

s(R)/180

µ

s (F)(1)

60ms (R)/75ms (F)

Load

E

O

max/I

O

max,

Vout between zero and E

O

max, mea-

sured between 10% and 90% of E

O

max

Current Fast

Mode:

Slow Mode:

200

µ

s(R)/200

µ

s (F)

60ms (R)/75ms (F)

Load

E

O

max/I

O

max,

Iout between zero and I

O

max, measured

between 10% and 90% of I

O

max

Transient recovery to load
change (Amplitude/time con-
stant)

Voltage

Fast Mode 5% E

O

max/100

µ

sec

Vout=400 Vdc and load switched
between infinity and 400/I

O

max

Slow Mode 0.5% E

O

max/1 msec

Source Current Fast Mode 50% I

O

max/100

µ

sec

Iout = I

O

max

and load switched between
0.1 x E

O

max/I

O

max and

E

O

max/I

O

max

Small signal 3-dB Bandwidth
(Fast Mode)

Voltage 2.5 KHz

Load = E

O

max/I

O

max,

Vprog out = 200V d-c (from keypad)
Vv analog in = 0.2 V rms (from analog
input terminal)

Current 2.3 KHz

Load = E

O

max/I

O

max,

Iprog out = 200 x I

O

max/E

O

max (from

keypad)
Vc analog in = 0.2 V rms (from analog
input terminal)

Slew rate (Fast Mode)

Voltage >1.2% E

O

max (V/

µs)

Load

E

O

max/I

O

max,

Measured as the chord of the exponential
response to a square waveform between
zero and E

O

max and back to zero.

Current >1.1% I

O

max (mA/

µs)

Load = calibrated shunt
Measured as the chord of the exponential
response to a square waveform between
zero and I

O

max and back to zero.

Overshoot

None

Turn ON/Turn OFF

Output Impedance

See Table 1-1.

Remote Sensing Range
(default = local sensing)

0.5 V d-c per lead

Provisions for 4-terminal (Kelvin) connec-
tion to load

D-C Isolation voltage

BHK 300-130MG,

BHK 500-80MG,

BHK 1000-40MG

1KV d-c or p-p plus max.
output voltage

Between either output terminal and
ground

BHK 2000-20MG 0.5KV d-c or p-p plus max.

output voltage

Between either output terminal and
ground

(1) Programming rise time (R)/fall time (F) for BHK 2000-20MG (Voltage, Fast Mode): 275

µ

s(R)/275

µ

s (F)

TABLE 1-2. BHK-MG 40W SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION

Advertising