KYORITSU 6016 User Manual

Page 3

Advertising
background image

11. Earth tests ............................................................................................................. 43

11.1 Principles of Earth Measurement ................................................................. 43

11.2 Earth resistance Measurement .................................................................... 43

12. Phase Rotation tests ............................................................................................. 45
13. Volts ....................................................................................................................... 46
14. Touch Pad ............................................................................................................. 46
15. Back Light ............................................................................................................. 46
16. Memory Function .................................................................................................. 47

16.1 How to save the data ................................................................................... 47

16.2 Recall the saved data ................................................................................... 49

16.3 Delete the saved data .................................................................................. 50

16.4 Transfer the stored data to PC ..................................................................... 52

17. General ................................................................................................................. 53
18. Battery replacement .............................................................................................. 54
19. Fuse replacement ................................................................................................. 54
20. Servicing ............................................................................................................... 55
21. Case and strap assembly ...................................................................................... 56

The KEW6016 incorporates Anti Trip Technology (ATT) which electronically bypasses
RCDs when performing loop impedance tests. This saves time and money by not having
to take the RCD out of the circuit during testing and is a safer procedure to follow.
With the ATT function enabled , a test of 15mA or less is applied between line & earth.
It enables loop impedance measurements without tripping RCDs rated at 30mA and
above.
Please read this instruction manual carefully before using this equipment.

Advertising