Spectrex Series 300 Open-Path Gas Detection System User Manual

Page 30

Advertising
background image

Spectrex Inc. - SafEye

TM

300 Gas Detector Manual – TM 794100, Rev. D, May 2004

22

4.4 Environmental Specifications
The SafEye system is designed to withstand harsh environmental conditions.
The Source and Detector units compensate for adverse conditions while
maintaining accuracy.

High Temperature:

Designed to meet MIL-STD-810C, method 501.1 procedure II
Operating temperature:

+158 ºF (+70 º C)

Storage temperature:

+158 ºF (+70 º C)

Low Temperature:

Designed to meet MIL-STD-810C, method 502.1, procedure I
Operating temperature:

-4 º F (-20 º C)

Storage temperature:

-40 º F (-40 º C)

Humidity:
Designed to meet MIL-STD-810C, method 507.1, procedure IV
Relative humidity of up to 95% for the operational temperature range.

Salt and Fog:
Designed to meet MIL-STD-810C, method 509.1 procedure I.
Exposure to a 5% salt solution for 48 hours.

Water and Dust:
IP67 per En60529
IP66 per En60529

Dust:

Totally protected against dust.

Liquids:

Protected against immersion between 15 cm and 1m in depth.
Protected against all water jets from all directions.

Shock and Vibration:

Vibration:

Designed to meet MIL -STD-810C, method 514.2,
procedure VIII.

Mechanical Shock:

Designed to meet MIL-STD-810C, method 516.1,
procedure I.

Electromagnetic Compatibility (EMC):
The detector is designed and approved according to the following EMC
requirements:
Electrostatic Discharge (ESD)

IEC1000-4-2:1995-1

Conducted emission

EN55011, Class B

Radiated emission

EN55011, Class B

Radiated immunity

ENV50140:1994 (80-1000 MHz)

EFT/B

IEC801-4: 1988

Advertising