Spectrex Series 300 Open-Path Gas Detection System User Manual

Page 58

Advertising
background image

Spectrex Inc. - SafEye

TM

300 Gas Detector Manual – TM 794100, Rev. D, May 2004

50

7.2.1 Routine Optical Surface Cleaning

The SafEye system, being an optical device, must be kept as clean as possible.
The optical surfaces concerned are the Source and Detector viewing windows.
To clean the optical window, proceed as follows:

1. Turn off the power to the SafEye detector and source.
2. Where dust or dirt has accumulated on the optical surface, clean the

surface with a small, soft-bristle brush.

3. The surfaces must then be washed thoroughly with water and a mild non-

abrasive detergent.

4. Thoroughly rinse the glass surface with clean water; ensuring no residue

is left behind.

5. Dry the glass with a clean dry soft cloth.
6. Enter in the Maintenance Logbook: Date, name of person and company

who performed the maintenance service.

7. Turn on power to the SafEye detector and source.
8. Perform signal verification (section 7.2.2).
9. Perform zero calibration (see section 6.6).
10. Perform functional check (see section 6.7)

7.2.2 Signal Verification
The Signal Intensity Check determines if there is a misalignment or if the Light
Source signal is wearing over a period of time. Clean the optical surfaces prior to
performing this check (see 7.2.1). This procedure should be performed in clear
weather.

1. Enter Alignment Mode by placing the mode selector on the side of the

detector for 2 seconds.

2. Within the first 20 seconds the Detector indicates 3 different indication

levels. See Table 1

3. Wait 20 seconds and count the number of LED flashes with the color, and

adjust the value (see Table 18).

4. Record the new results in the maintenance log book.
5. Determine the absolute variance compared with the previous alignment

reading in the maintenance logbook.

6. If the variance is more than 30%, perform alignment (see section 6) and

zero calibration (see section 6.6). Call a technician for service if the SIC is
less than 66 with both LED’s flash in red color.

Table 18. LED Signal Adjustment

Color (left-right)

Number to be

added

Red-Red

0

Orange-Orange

62

Green-Orange

124

Green-Green

186

Advertising