Installation Manual

7 . Place a lock washer and nut on each bolt and tighten the nuts 100…150 inch-pounds to ensure the gateway is

sufficiently secured to the pole .

8 . Repeat Steps 7 and 8 for attaching the V-block clamp mounting hardware to the bottom bolts of the

mounting backplate .

Side View

Back View

Side View

Figure 12: Completed gateway mounting

Banding Mounting

Banding mounting equipment is sized to mount the gateway on a 2-1/2…24-inch outer diameter pole .

MPORTTNT

I

When using the banding mounting kit for the gateway, use BAND-IT Idex installation practices. Refer to

www.band-it-idex.com/en/Literature/Tool_Instructions/P05886.pdf

for more information. This is especially applicable when

mounting on a non-tapered vertical pole, as the banding could loosen over time resulting in the unit sliding down the pole.

To mount the gateway on a pole, gather the banding and locking equipment .

Figure 13: Banding and locking equipment