ORION® Fixed Network (SE) II Network Gateway Transceiver

TC Power

Badger Meter provides an Emerson AC-to-DC power supply with cord (66528-003) that plugs into a standard

three-prong 120V AC outlet . If you are powering the gateway directly via DC power, see

"CDMA, GPRS or LAN with DC Power

Source" on page 20

.

Figure 27: 120V AC power supply with power cord

NOTE:

N

If you replace a gateway, make sure to replace the power supply cord with the Emerson power supply cord at the

same time .

Lightning Trrestors

Lightning arrestors are recommended for all standard and

remote antenna installations . If lightning arrestors are

used, they should be placed directly between the gateway

enclosure and the antenna cable connector and grounded

per code . One lightning arrestor is shown in Figure 28 . Arrows

indicate where other lightning arrestors should be attached .
Lightning arrestors for both the TX/RX antennas as well

as the backhaul antenna (if applicable), should meet the

following specifications:

Operating bandwidth: 800…2400 MHz

Impedance: 50 Ω

Power handling (average): 2 W, minimum

Environmental/weather rating suitable for

the location

N male connector on the protected side;

N female connector on the surge side

Figure 28: One lightning arrestor attached (ground is not pictured).

Arrows indicate where additional lightning arrestors should

be attached.