3 . Grasp and pull to remove the battery from the unit (Figure 44) and safely discard the battery (see

"Battery Disposal" on

page 33

) .

Figure 44: Battery removal

4 . Place the new battery into the enclosure with the battery label “This Side Out” visible, as shown .
5 . Carefully install the battery connector onto the circuit board . Insert the connector only far enough so that the

connector latch engages . Verify that proper connector polarity is observed .

6 . Install the new enclosure cover provided with the battery kit . Tighten each of the four cover screws to

16 inch-pounds, maximum, being careful to not overtighten any of the screws .

Battery Disposal

The battery contains lead and should be handled and disposed of in accordance with local, state and federal regulations .

Refer to the Badger Meter Battery Handling Safety Guide, available at

www.badgermeter.com

, for more information .

FAILURE TO PROPERLY DISPOSE OF A LEAD ACID BATTERY MAY RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE

FROM ACID BURNS.