Requesting historical interval data manually, Historical interval data – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 27

Advertising
background image

Historical Interval Data

Whether initiated automatically or manually, the ORION field application software is capable of extracting historical profile

data from an ORION Migratable endpoint at the following intervals:

7 days (Week)

14 days (Two weeks)

30 days (One month)

60 days (Two months)

All readings stored in the endpoint

(Shorter months include extra days of readings, up to 30)

(Up to 90 days of hourly readings or 2160 reads)

This chart shows the number of readings collected for meters set at 60 minute (hourly) intervals and at 15 minute (quarter

hourly) intervals:

Available Profile Data

Extraction Intervals

Hourly Reads:

1 Read per Hour

24 Reads per Day

15 Minute Reads:
4 Reads per Hour
96 Reads per Day

7 days

168 reads (24 x 7)

672 (96 x 7)

14 days

336 reads (24 x 14)

1344 (96 x 14)

30 days

720 reads (24 x 30)

2160 (96 x 22 5)

60 days

1440 reads (24 x 60)

2160 (96 x 22 5)

All/90 days

2160 reads (24 x 90)

2160 reads (96 x 22 5)

NOTE:

N

The ORION Migratable endpoint (or Fixed Network in mobile mode) is capable of holding up to 90 days of hourly

interval data, or 2160 hourly reads If the account is set up to read every 15 minutes – 4 readings per hour –

the data extracted reflects four (4) readings per hour and reaches the maximum 2160 reads in 22 5 days

(90 days / 4 = 22 5 days)

Requesting Historical Interval Data Manually

If a work item was not assigned by the reading data management operator, you can manually initiate a request for the

historical interval data from the current ORION Migratable or Fixed Network (mobile mode) endpoint by performing the

following steps

1 Tap the Work Items button on the account read

screen for an ORION ME account
Result: The work Items screen opens.

NOTE:

N

If a work item is set to be performed

automatically, the message says "Assigned"

and the Collect button is inactive

Figure 36: historical Interval data

REAdINg A ROuTE

Page 27

April 2014

ORION® Field Application for Trimble® Ranger 3

Advertising
This manual is related to the following products: