A-100ne, Enable and program the tfd and fvs systems, 3 mode 1 - manually adjusting the output – Blue-White A-100N FLEXFLO Peristaltic Pump User Manual

Page 12

Advertising
background image

!

Enable and Program the TFD and FVS Systems

The TFD and FVS systems must be enabled.

+ Set the pump for mode 0. Press the MODE button until MODE 0 is

shown on the LCD display.

A-100NE

Page 12

+ Press the DIGIT button to set the number of seconds of alarm delay time.

The number will increase to a maximum of 256 seconds and roll over to
OFF.

+ To exit the programming mode, press the RUN/STANDBY button and the

MODE button at the same time. The arrow next to the word PROGRAM
will disappear and an arrow will appear next to the word RUN.

NOTE: If while in the program mode no buttons are pressed within 60
seconds, the circuitry will automatically return to the run mode.

+ Enter the programming mode. At the same

time, press the RUN/STANDBY button and
the MODE button. A blinking ARROW will
point to the word PROGRAM indicating the
program mode has been activated. The TFD
icon will blink. The word ON will display
indicating the TFD system is activated.

+ Press the DIGIT button to toggle the system

on and off.

+ Press the MODE button to enter the FVS

system programming. The FVS icon will
blink. The display will indicate the current
alarm delay time setting in seconds. (000 =

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

0

On

MODE

TFD

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

0

001

MODE

FVS

SEC

6.3 Mode 1 - Manually adjusting the output

- In this mode, the pump

is turned on and off by an electronic cycle timer. The pump will energize for
the duration of the “on time” and de-energize for the remainder of the “total
time” thus completing one cycle. The cycle then repeats.
The “on time” and “total time” cycles are independently adjustable from 0.1
to 199.9 units of measure with a 0.1 unit resolution. The units of measure
can be seconds, minutes, hours or days.
Example: If the “total time” cycle is adjusted for 90 seconds and the “on
time” portion of the cycle is adjusted for 5 seconds, the pump will run for 5
seconds and turn off for 85 seconds (90 second total cycle). This cycle is
repeated until either the standby button is pressed, the cycle time is changed
or the input power is disconnected from the pump.

+ Set the pump for mode 1. Press the MODE button until MODE 1 is

shown on the LCD display.

A-100NE

Page 13

+ Enter the programming mode. At the same

time, press the RUN/STANDBY button and
the MODE button. A blinking ARROW will
point to the word PROGRAM indicating the
program mode has been activated. The total

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

1

199.9

MODE

TOT-TSEC

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

1

42.5

MODE

ON-T

SEC

selected time unit icon will be displayed. The current total time setting will

be displayed and the left most (selected) digit will blink. The decimal is fixed
and cannot be moved.

+ Pressing the DIGIT button will increase the selected digit.
+ Pressing the FIELD button will select a new the digit to the right or the

time unit.

+ Press the DIGIT button to increase the selected digit or time unit.

+ Press the MODE button to exit the total

time programming screen and enter the on
time programming screen. The ON-T icon
will blink. The currently selected time unit
icon will be displayed. The current on time
setting will be displayed and the left most
(selected) digit will blink.

+ Pressing the DIGIT button will increase the selected digit.
+ Pressing the FIELD button will select a new the digit to the right or the

time unit.

+ Press the DIGIT button to increase the selected digit or time unit.
+ At the same time, press the RUN/STANDBY button and the MODE

button. A blinking ARROW will point to the word RUN indicating the run
mode has been activated.

NOTE: If while in the program mode no buttons are pressed within 60
seconds, the circuitry will automatically return to the run mode.

Advertising