5.3 External Input Signal Connections

The pump will accept a variety of external control input signals; 4-20 mA ,
0-10 VDC, TTL, CMOS, AC Sine Waves, Contact Closures, Hall Effect,
NPN. The 4-20mA and 0-10 VDC loops must be powered.
All wiring connections are to be made inside of the junction box located on
the side of the pump. Special connectors are not required. A liquid-tite
connector is supplied and should be used for the external signal cable. The
signal input wires are color coded to the type of signal being used.

INPUT

VOLTAGE

115V 60Hz

220V 50Hz

HOT

LEADWIRE

NEUTRAL

LEADWIRE

GROUND

LEADWIRE

230V 60Hz

YELLOW

YELLOW

YELLOW

BLUE

BROWN

RED

GREEN

GREEN

GREEN

MOTOR LEADWIRES

SIGNAL INPUT WIRE COLOR CODES

WIRE COLOR CODE

INPUT TYPE

MOTOR ON SIGNAL

5-20V DC open collector output

closed while motor is energized

FLOW VERIFICATION SENSOR

4-20 mA

0-10 VDC

ALARM RELAY

BROWN (+) & BLACK (-)

PURPLE & PURPLE

WHITE (+) & BLACK (-)

BLUE (+) & BLACK (-)

TTL, CMOS

ORANGE (+) & BLACK (-)

RED/WHITE (+ 20VDC) & BLACK (-) & YELLOW (signal)

CONTACT (10v @ 2 mA max)

HALL EFFECT, NPN

RED (+) & WHITE (-)

PADDLEWHEEL SENSOR SIGNAL INPUT WIRING

PADDLEWHEEL SENSOR

WIRE COLOR CODE

BLUE-WHITE

PADDLEWHEEL

SENSOR TYPE

MODEL FH

HALL EFFECT SENSOR

BLACK (-)

RED (+)

PUMP INPUT

WIRE COLOR CODE

MODEL FC

AC SINE WAVE SENSOR

BARE (signal)

BLACK (-)

RED (+ 20VDC)

WHITE (signal)

BLACK (-)

RED (+)

BLACK (-)

WHITE (+)

A-100NE

Page 7

ACCEPTABLE CABLE JACKET RANGE:

.118 - .255 INCH .( 3,0 - 6,5 MM)

EXTERNAL INPUT CABLE

CIRCUIT BOARD CONNECTIONS

AC

MOTOR

Neutral (blue/brown/red)

Hot (yellow)

Ground (green)

Ground (green)

Common

Hot

AC

Input

Power

Power Circuit Board

(Top view)

Protector Fuse

2 Amps, 250 Volt AC

(little Fuse #235002

or Equivalent)

R R

2A

250VAC

T3

T2

T1

T4

LINE

HOT

LINE

NEUTRAL

MOTOR

NEUTRAL

MOTOR

SWITCHED

115V 50/60Hz

INPUT VOLTAGE
RESISTOR PLACEMENT

220V 50/60Hz
230V 50/60Hz

R R

R

MA = BLUE

GND = BLACK

RELAY = PURPLE (2)

VDC = ORANGE

VS = RED (+17V DC)

PLS = WHITE

JUNCTION BOX

LIQUID-TIGHT
CONNECTOR

MTR = BROWN

Alarm Relay

3A/125VAC

N/C

COM

N/O

Purple connection wires

Default is N/O

VS
VDC
MA
MTR
GND
PLS

CN3

VS

FVS
GND

TFD
GND

FVS+

CN4

Control Circuit Board

(Back view)

Program Disable Jumper - Located on front of Control board.
Un-installed = enable front panel programming (default)
Installed = disable front panel programming

External input connections

6 Wire bundle to junction box

Flow verification sensor connector

3 Wire bundle to junction box.

red/black/yellow

Tube failure detection sensor connector

2 Wire bundle to pump head sensor

(A-100N series pumps only)

Advertising