A-100ne, 4 how to install the tubing and fittings, 0 how to operate the pump 6.1 pump output controls – Blue-White A-100N FLEXFLO Peristaltic Pump User Manual
Page 9: Page 8, Page 9
A-100NE
Page 8
5.4 How To Install the Tubing and Fittings
! Inlet Tubing - Locate the inlet fitting of the Pump Tube. Remove the tube
nut. Push the clear PVC suction tubing onto the compression barb of the
fitting. Use the tube nut to secure the tube. Hand tighten only.
CAUTION: Proper eye and skin protection must be
worn when installing and servicing the pump.
Foot
Strainer
Ceramic
Weight
Tubing
Suction 3/8"
! Strainer - Trim the inlet end of the suction tubing so that
the strainer will rest approximately two inches from the
bottom of the solution tank. This will prevent sediment
from clogging the strainer. Slip the ceramic weight over the
end of the suction tube. Press the strainer into the end of
the tube. Secure the ceramic weight to the strainer. Drop
the strainer into the solution tank.
! Outlet Tubing - Locate the outlet fitting of the Pump
Tube. Remove the tube nut. Push the opaque outlet
(discharge) tubing onto the compression barb of the fitting.
Use the tube nut to secure the tube. Hand tighten only.
Keep outlet tube as short as possible.
! Injection/Check Valve Fitting Installation - The
Injection/Check valve fitting is designed to install directly
into either 1/4” or 1/2” female pipe threads. This fitting will
require periodic cleaning, especially when injecting fluids
that calcify such as sodium hypochlorite. See section 7.0.
Install the Injection/Check valve directly into the piping
system. To prevent trapped gasses, install the fitting in an
upward direction. Use PTFE thread sealing tape on the pipe
threads.
Push the opaque outlet (discharge) tubing onto the compres-
sion barb of the Injection/Check valve fitting. Use the tube
nut to secure the tube. Hand tighten only.
Inlet Adapter
Outlet Adapter
Pump Head
RUN
STANDBY
RUN
FIELD
DIGIT
MODE
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
INPUT MODES
1 - MANUAL
2 - 4-20mA
3 - 0-10VDC
4 - 0-1000 Hz
PROGRAM
RESET SERVICE
PRIME
DISPLAY
DIGITAL TIMER PUMP
1000
MODE
5 - PULSE (BATCH)
A-100NE
Page 9
6.0 How to operate the pump
6.1 Pump Output Controls
-
Open the control panel door by sliding the
upper and lower slide clamps to the left.
! RUN/STANDBY Button -
+ Press to start and stop the pump.
ARROW next to the word RUN will light
when in the run mode. The ARROW next
to the word STAND-BY will blink when in
The
+ Press to clear ALARM.
+ When pressed with the FIELD Button, initiates a 99 second prime cycle
which temporarily overrides the mode setting and runs the pump motor at
100% speed. The ARROW next to the word PRIME will blink.
+ When pressed with the DIGIT button, resets the 500 hour service warning
timer to zero.
+ When pressed with the MODE button, initiates the programming mode.
The ARROW next to the word PROGRAM will blink.
! FIELD Button -
+ In the programming mode, selects the digit to be changed.
! DIGIT Button -
+ In the programming mode, increases the selected digit.
+ When pressed with the MODE Button, toggles the display from operating
time cycle values to input signal value.
! MODE Button -
+ Used to select one of five operating modes.
Mode 0 - TFD system and FVS system set-up
Mode 1 - Manual Adjustment (external input disabled)
Mode 2 - 4-20mA input
Mode 3 - 0-10VDC input
Mode 4 - Frequency input adjusts cycle on-time
Mode 5 - Pulse input count = single batch time
RUN
STANDBY
RUN
FIELD
DIGIT
MODE
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
INPUT MODES
1 - MANUAL
2 - 4-20mA
3 - 0-10VDC
4 - 0-1000 Hz
PROGRAM
RESET SERVICE
PRIME
DISPLAY
DIGITAL TIMER PUMP
1000
MODE
5 - PULSE (BATCH)
RUN
STANDBY
RUN
FIELD
DIGIT
MODE
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
INPUT MODES
1 - MANUAL
2 - 4-20mA
3 - 0-10VDC
4 - 0-1000 Hz
PROGRAM
RESET SERVICE
PRIME
DISPLAY
DIGITAL TIMER PUMP
1000
MODE
5 - PULSE (BATCH)
SLIDE CLAMP
1000