5.0 Installation
Note: All diagrams are strictly for guideline purposes only. Always consult
an expert before installing the pump into specialized systems. The pump
should be serviced by qualified persons only.
5.1 Mounting Location
Choose an area located near the chemical supply tank, chemical injection
point and electrical supply. Although the pump is designed to withstand
outdoor conditions, a cool, dry, well ventilated location is recommended.
Install the pump where it can be easily serviced.
! Mount the pump to a secure surface or wall using the enclosed hardware.
Wall mount to a solid surface only. Mounting to drywall with anchors is not
recommended.
! Mount the pump close to the injection point. Keep the outlet (discharge)
tubing as short as possible. Longer tubing increases the back pressure at the
pump tube.
! Your solution tank should be sturdy. Keep the tank covered to reduce
fumes. Do not mount the pump directly over your tank. Chemical fumes
may damage the unit. Mount the pump off to the side or at a lower level
than the chemical container.
! Mounting the pump lower than the chemical container will gravity feed the
chemical into the pump. This “flooded suction” installation will reduce
output error due to increased suction lift. You must install a shut-off valve,
pinch clamp or other means to halt the gravity feed to the pump during
servicing.
! Be sure your installation does not constitute a cross connection with the
drinking water supply. Check your local plumbing codes.
! Be sure to install a back-flow prevention check valve.
! An anti-syphon valve is not required. syphoning cannot occur.
A-100NE
Page 4
CAUTION: Proper eye and skin protection must be
worn when installing and servicing the pump.
Floor Mount
Wall Mount
7-3/8”
7-5/8”
3-1/2”
8-3/16”
Drill .156 Dia. (5/32)
For Self-Tap Screw
#10 X 1” Phillips Steel
4 Places
Drill .156 Dia. (5/32)
For Self-Tap Screw
#10 X 1” Phillips Steel
2 Places
INJECTOR MOUNTING
Note: For wall-mounting, drill & thread into
solid wood only.
A-100NE
Page 5
TYPICAL INSTALLATION
R
Suction
Tube
Chemical
Container
with cover
RUN
STANDBY
RUN
FIELD
DIGIT
MODE
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
INPUT MODES
1 - MANUAL
2 - 4-20mA
3 - 0-10VDC
4 - PULSE (Hz)
PROGRAM
RESET SERVICE
PRIME
DISPLAY
VARIABLE SPEED PUMP
SERVICE
1000
ALARM
Discharge
Tube
Strainer
Ceramic Weight
Injection / Check valve
with 1/4” and 1/2” male
pipe threads.
Mount in upward position
to prevent trapped gasses
in the injection fitting.
Wall or shelf mount
away from the top of the
solution tank. Chemical
fumes can damage the
unit.
5.2 Input Power Connections
! Be certain to connect the pump to the proper supply voltage. Using the
incorrect voltage will damage the pump and may result in injury. The
voltage requirement is printed on the pump serial label.
! Removable resistors on the circuit board are factory preset for the correct
voltage. See page 7 Circuit Board Connections diagram for details.
! The pump is supplied with a ground wire conductor and a grounding type
attachment plug (power cord). To reduce the risk of electric shock, be
certain that the power cord is connected only to a properly grounded,
grounding type receptacle.
Note: When in doubt regarding your electrical installation, contact a
licensed electrician.
WARNING: Risk of electric shock.
9
2
1
Control
Control Cover
Pumphead
Junction Box
Rear Plate
Pumphead
Cover
6.0
Pumptube
Assembly
Rotor
Assembly
9
8
1
Slide Clamps**
RUN
STANDBY
RUN
FIELD
DIGIT
MODE
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
INPUT MODES
1 - MANUAL
2 - 4-20mA
3 - 0-10VDC
4 - PULSE (Hz)
PROGRAM
RESET SERVICE
PRIME
DISPLAY
DIGITAL TIMER PUMP
PARTS LOCATOR DRAWING