0 flowmeter spu installation, 0 ultrasonic transducer installation, Proseries – Blue-White Sonic-Pro S4 Ultrasonic Flowmeters User Manual

Page 4: Sonic-pro, Caution risk of danger, Ok no no

Advertising
background image

Page 3

Sonic-Pro

The Sonic-Pro Flowmeter is shipped with the following items:

!

Sonic-Pro Flowmeter SPU (Signal Processing Unit)

!

Sonic-Pro Inline Pipe Fitting

!

Enclosure Mounting Hardware (not included in sensor mounted units)

2 mounting plates

4 mounting plate screws (10-32 x .50”)

2 wall mounting screws (#10 x 1.00”)

1 pipe mounting clamp (maximum pipe diameter 10”)

!

Instruction Manual

The Sonic-Pro was designed to be installed and operated by qualified personnel only. Do not
attempt to install or operate the meter if you are unsure. Seek qualified assistance. Please
note that warranty coverage does not include damage due to misuse or improper
installation.

If remote mounting the SPU, select a mounting location t

hat is within reach of the transducer

cables and power supply. The transducer cable must not be cut or modified. Note that the

Sonic-Pro can accurately measure flow from either direction.

The SPU can be mounted on a wall or on a horizontal or vertical run of pipe. Although the
Sonic-Pro is designed to withstand outdoor conditions. A cool, dry location, where the unit
can be easily monitored is recommended. Special ventilation is not required.

2.0 Flowmeter SPU Installation

2.1
Unpacking

2.2
Mounting
Location

2.3
Wall or Pipe
Mounting

When the SPU is not mounted directly to the Inline Fitting, the SPU must be installed on a
solid, secure surface
such as a solid wall, panel, wall studs, etc. DO NOT install the meter
on drywall with anchor bolts.

!

CAUTION

risk of danger

Do not position the equipment so that it is difficult to disconnect the power
supply cord.

The SPU can be mounted on horizontal or vertical pipe. The pipe must be secure and of
sufficient strength to support the weight of the SPU.

Page 4

Sonic-Pro

3.1
Pipe Fitting/
Transducer
Installation

3.0 Ultrasonic Transducer Installation

Minimum Straight Pipe Length Requirements

The Sonic-Pro’s sound wave beam is only affected by fluid that actually passes through the
beam and therefore, the meter will not measure with high accuracy if the fluid velocity is not
consistent across the entire pipe diameter. Flow disturbances such as pumps, elbows, tees,
and valves in the flow stream can cause swirl patterns and vortices that will affect the
measurement accuracy or disrupt flow measurement capability. Install the transducers on a
straight run of pipe as far as possible from any disturbances. The distance required for high
accuracy will depend on the type of disturbance.

Transducer Mounting Requirements

!

The meter can be mounted on horizontal or vertical runs of pipe.

!

Mounting anywhere around the diameter of vertical pipe is acceptable, however, the pipe
must be completely full of fluid at all times.

!

Back pressure is required on downward flows to ensure a full pipe.

!

See the minimum straight length of pipe requirement chart above.

!

Related piping must be independently supported. The meter should not be allowed to
support the weight of related piping.

Type of Disturbance

Straight Lengths of Pipe Required

Upstream from Transducers

Flange

5 x Nominal Pipe Size

Reducer

o

90 Elbow

Gate valve or Pump

Downstream from Transducers

o

Two 90 Elbows - 1 Direction

o

Two 90 Elbows - 2 Directions

5 x Nominal Pipe Size

7 x Nominal Pipe Size

5 x Nominal Pipe Size

10 x Nominal Pipe Size

5 x Nominal Pipe Size

15 x Nominal Pipe Size

5 x Nominal Pipe Size

20 x Nominal Pipe Size

5 x Nominal Pipe Size

25 x Nominal Pipe Size

5 x Nominal Pipe Size

OK

OK

OK

NO

NO

Down flows

must have

back pressure

Pipe must be full

Air could be trapped

!

L >= 5D

L >= 10D

See minimum straight length requirements above

INLINE PIPE FITTING

TEMPERATURE VS PRESSURE

PVC Adapters

HDPE and 316SS Adapters

0

50

100

150

200

250

WORKING PRESSURE (PSI/g)

70° F (21° C)

110° F (43° C)

150° F (65° C)

TEMPERA

TURE F (C)

300

80° F (27° C)

90° F (32° C)

100° F (38° C)

120° F (49° C)

130° F (54° C)

140° F (60° C)

160° F (71° C)

8.00 in

[20.3 cm]

Industries, Ltd.

Industries, Ltd.

ProSeries

by Blue-White Ind.

d

Industries, Ltd.

Industries, Ltd.

ProSeries

by Blue-White Ind.

d

Advertising