Starting problems

Fault

Cause

Remedy

"No air" on display

No air has been exhausted.

Fan blocked.
Vacuum valve does not connect.

Plug of vacuum valve is not inserted.

Clean fan.
Clean outlet tube.
Eliminate the fault.
Check if the valve’s switch connects.
Check position/switching point of the switch.
Insert the plug in the right input of the control.

"No speed" on

display

Malfunction frequency converter.
Frequency converter out of order.
Plug of drive is not inserted.
Speed sensor does not detect pulses.

See page 44.
See page 44.
Insert the plug in the right input of the control.
Adjust distance chain wheel and sensor to 1mm.
Out of order, replace sensor.

"No heat" on

display

Burner in reset.
Ionization follow-up cable not inserted well in

contact of burner.
Plug of heating is plugged out of the burner.
No gas in pipe at first set-up.

Overheat switch tripped.
Fuse gas control broken.

Open gas tap and reset burner.
Insert plug well in burner and control print.

Insert plug in right input of the control.
Make many start attempts, with resets in the

meantime, so that air is removed from the pipes.
Check system and reset switch.
Replace fuse after controlling system.

"Foot" on display

Foot pedal is operated.

Release the foot pedal.
Readjust the switch.
Tighten the springs.

"Heat1" or

"Heat2" on display

(number of the

defective sensor)

Temperature sensor cable interrupted.
Temperature sensor out of order.
Input on control out of order.

Check cable and repair defects.
Replace the sensor by a new one.
Replace the control by a new one.

Frequency converter

Fault

Condition

Possible cause

OI.AC**

Drive output instantaneous over current. Insufficient ramp times.

Phase to phase or phase to ground short circuit on the drives

output.
Drive requires autotuning to the motor.
Motor or motor connections changed, re-autotune drive to motor.

It.AC

I²t on drive output current.

Excessive mechanical load.
High impedance phase to phase or phase to ground short circuit

at drive output.
Drive requires re-autotuning to motor.

HFxx trip

Hardware faults.

Internal drive hardware fault.

Advertising