Alliance Laundry Systems CI 2050/325 User Manual

Page 45

Advertising
background image

45

6

Control of exhaust ventilator

The exhaust ventilator always turns on maximum when the ironer is switched on. An underpressure

switch is mounted, which controls the working of the exhaust ventilator. The function of this

underpressure switch is controlled when starting up the machine and will give a warning sign when the

function is not correct.

Speed control

The speed is controlled by means of a frequency regulator, which is controlled by a feedback system

through the microprocessor board.
The speed is checked by an approximated switch, which is activated by the teeth of a detection wheel.

Start/stop function

The ironer can be started and stopped by pressing the 0/I button.
The foot pedal can temporarily stop the ironer.

approximated switch

teeth of a detection wheel

Advertising