Alliance Laundry Systems CI 2050/325 User Manual

Page 43

Advertising
background image

43

5

3 mm

Fig. 1

Fig. 2

Burner

Fault

Cause

Remedy

Continuous

malfunction

after reset

No supply voltage so also no burning

reset lamp.
Overheat.
Short-circuit electrode to earth.

Check fuses and wiring.

Check overheat thermostat (see Fig. 1).
Adjust electrode properly -> ignition probe: 3 mm from burner

(see Fig. 2).

Malfunction

burner after

2 start

attempts

No gas supply.

No ignition spark.

No ignition while there is a spark.

Check gas supply, gas tap and function of the gas valves.

Adjust electrode properly.

Machine has no contact with earth.

Check electrical connection of the machine.

Check overheat thermostat.

No gas supply.

Wrong adjustment gas valve.

No PWM signal on ventilator (turns full at spark).

thermostat

Fault

Condition

Solution

OVL.d

I x t overload (I = current, t = time).

Reduce motor current (Load).

hot

Heatsink/IGBT temperature high.

Reduce ambient temperature or reduce motor current.

br.rS

Braking resistor overload.

Call Customer Service.

AC.Lt

Drive is in current limit.

Call Customer Service.

Advertising
This manual is related to the following products: