Cleaning Recommendations for Clogged Filtration Discs

Water-formed deposits may cause clogging of the filter discs. The formation of these deposits

depends on the quality of the filtered water and environmental conditions like temperature, pH,

light, duration of filtration and more.

Common water-formed deposits are:

Biological or organic deposits (mostly mucous or oily to the touch, beige, brown or green

in color)

Iron oxide (rust) or other metal oxides

Carbonates (white or gray deposit)

Combinations of the above

If these deposits cannot be eliminated by pretreatment of the water, we recommend the following

cleaning procedure:

Material and Equipment

A well ventilated working place.

2 small containers (1 liter), 2 large containers (15 liter) and a stirring stick, all resistant to

chemicals, preferably of polypropylene.

Plastic rope to tie up the disc.

Sodium Hypochlorite NaOCl -

Strong oxidizing liquid, commercial concentration: 10%.

Oxidizes and removes organic and biological deposits.

Hydrochloric Acid HCl -

Very corrosive liquid, commercial concentration: 30%.

Dissolves and removes carbonates, iron oxide, and other deposits.

Safety equipment: safety glasses, gloves, long pants, long sleeved shirt and shoes.

ATTENTION!

While working with chemicals protect yourself with the necessary safety equipment:

Safety glasses, gloves, protective clothing

Work in a well ventilated area