Cleaning Complex Deposits

If the composition of the deposit is not known, perform the following test:

Take 5 discs for the test.

Soak 2 discs in a 5% Sodium Hypochlorite Solution.

Preparation of the solution:

Pour 1 cup of water into a small container, then add 1 cup of Sodium Hypochlorite

(10% NaOCl).

Soak 2 discs in a 5% Hydrochloric Acid Solution.

Preparation of the solution:

Pour 2½ cups (= 500ml) of water into a small container, then add carefully

½ cup (= 100ml) of Hydrochloric Acid (30% HCl).

Keep one disc as a control.

Observe the cleaning process:

- If one of the solutions removes all of the deposit, clean the discs in that solution

according to the instructions above.

- If neither solution removes the deposit completely, continue with the test procedure.

Remove the discs from both solutions, rinse them well with water and soak them in the

second solution: put the two discs, which have been in the Sodium Hypochlorite Solution,

in the Hydrochloric Acid Solution, and the other way round.

Check the cleaning process:

- If one of the treatments removes all of the deposit, clean all of the discs following the

same two-step procedure in the exact same order. Rinse the discs well between the

two cleaning processes.

- If the deposit hasn’t been completely removed, send a set of untreated discs to the

laboratory for further examination.