4 inch vent installation – Takagi T-H3M-IN/OS User Manual

Page 14

Advertising
background image

14

Page

Installation

Installation Manual

3 inch vent installation

1.  Connect a 3" elbow directly on the

intake vent collar of the water heater

2.  Connect a 3" coupling directly on the

exhaust vent collar of the water heater

Make sure the couplings engage

the o-rings installed in the intake

and exhaust vent collars

3.  Connect a 3" straight pipe to

the coupling

3"coupling

Exhaust

vent collar

(Female)

3" straight pipe

3" coupling

Intake vent

collar

(Female)

3" straight pipe

1.  Connect 3" couplings directly on

the exhaust and intake vent collar

of the water heater

Make sure the couplings engage

the o-rings installed in the intake

and exhaust vent collars

2.  Connect 3" straight pipes to the

couplings

For details of the optional items, refer to the Installation manual for each optional item

Vent connections for two-pipe

Vent connections for single pipe

3" coupling

3" straight pipe

Exhaust

vent collar

(Female)

* 3" elbow with

bird screen

Intake vent

collar

(Female)

*The water heater came with a metal screen

that will fit into a 3 inch elbow

For details of the optional items, refer to the Installation manual for each optional item

1.  Connect 3"x4" increasers

directly on the exhaust and intake

vent collar of the water heater

Make sure the couplings engage

the o-rings installed in the intake

and exhaust vent collars

2.  Connect 4" straight pipes to

the increasers

4" straight

pipe

3"x4" increaser

Exhaust

vent

collar

(Female)

Intake vent

collar

(Female)

4" straight

pipe

3"x4"

increaser

4" straight pipe

3"x4" increaser

Exhaust vent

collar (Female)

* 3" elbow with

bird screen

Intake vent

collar

(Female)

1.  Connect a 3" elbow directly on the

intake vent collar of the water heater

2.  Connect a 3"x4" increaser directly on

the exhaust vent collar of the water

heater

Make sure the couplings engage

the o-rings installed in the intake

and exhaust vent collars

3.  Connect a 4" straight pipe to

the increaser

Vent connections for two-pipe

Vent connections for single pipe

*The water heater came with a metal screen

that will fit into a 3 inch elbow

4 inch vent installation