Temperature settings – Takagi T-H3M-IN/OS User Manual

Page 38

Advertising
background image

38

Page

Operation

Screen on the controller

1.

Turn on the 120 VAC power supply to the water

heater

2.

Press the "ON/OFF" button on the controller in

order to turn the controller on

3.

When ON, the STAND BY LED is lit

4.

It shows the set temperature on its display as shown

in the picture on the right (EX: 120 °F)

5.

Press the "HOT" button or the "COLD" button to set

the temperature setting of the unit

(EX: 120 °F)

TEMPERATURE SETTINGS

-Using Remote controller-

-Temperature setting on the PCB-

(Without Remote controller)

There are 2 preset temperatures (120 °F (49 °C) and 140 °F (60 °C)) that you can select from by changing

the DIPswitch settings on the computer board without the remote controller See the table below

When the remote controller is in normal operation, the set temperature of the remote controller is given

priority over the set temperature of the DIPswitch settings

• The temperature has been preset at the factory to 120 °F (49 °C)

Computer board

Bank of

DIPswitches

NOTE: Only change the switches with dark squares The dark squares

indicate the direction the DIPswitches should be set to

120 °F (49 °C)

DEFAULT

140 °F (60 °C)

No 9 : OFF

No 9 : ON

OFF

ON 1 2 3 4 5 6 7 8 9 10

OFF

ON 1 2 3 4 5 6 7 8 9 10

Normal Operation

Owner's Guide