Takagi T-H3M-IN/OS User Manual

Page 47

Advertising
background image

47

Page

Remote

Green

LED

Malfunction

description

Diagnosis

391

Two Times

Air-fuel ratio rod

failure

• Check for connection/breakage of wires (Part #708)

and/or soot on the AFR rod (Part #108)

510

Six Times

Abnormal main gas

solenoid valve

• Check for connection/breakage of wires (Part #707)

and/or burn marks on the computer board (Part #701)

• Check for signs of vent corrosion

• Check gas valve contacts and gas valve wire harness

connections for signs of rust or corrosion

551

Six Times

Abnormal gas

solenoid valve

• Check for connection/breakage of wires (Part #707)

and/or burn marks on the computer board (Part #701)

• Check gas valve contacts and gas valve wire harness

connections for signs of rust or corrosion

611

Four Times Fan motor fault

• Check for connection/breakage of wires, dust buildup

in the fan motor (Part #103) and/or burn marks on

the computer board (Part #701)

• Check for frozen/corrosion of connectors (Part #103)

701

One Time

Computer board fault • Check for connection/breakage of wires (Part #711)

711

One Time

Gas solenoid valve

drive circuit failure

• Refer to the 111 and 121 error codes

721

Six Times

False flame

detection

• Check if there is leaking from heat exchanger (Part #401)

741

N/A

Miscommunication

between water

heater and remote

controller

• Check the model type of the remote controller

• Inspect the connections between the water heater

and remote controller

• Check the power supply of the water heater

751

N/A

Miscommunication

between water heater

and temperature

controller

(Indoor

model only)

• Inspect the connections between the water heater

and temperature controller

• Check the power supply of the water heater

941

Five Times

Abnormal exhaust

temperature

(Indoor

model only)

• Check to see of the exhaust temperature is higher

than 149°F (65°C)

991

Five Times

Imperfect

combustion

• Check if the gas type of the water heater matches

the gas supplied to it

• Inspect the environment around the water heater

Determine how long the water heater has been

installed and match DIPswitches

• Check the altitude/elevation of the area of where

the water heater is installed

• Check if there is any blockage in the intake air and/

or exhaust

• If the water heater is installed as a direct-vent

system, check whether there is enough distance

between the intake air terminal and the exhaust

terminal

• Check if there is grease and/or dirt in the burner (Part

#101) and the fan motor (Part #103), especially if the

water heater has been installed in a contaminated area

• Check the DIPswitches match gas type of the water

heater

• Check the manifold pressure at Max and Min

• Check combustion chamber tube (part #117) to see if it

is clear and securely installed

Troubleshooting

Owner's Guide

Advertising