Takagi T-H3M-IN/OS User Manual

Page 44

Advertising
background image

44

Page

PROBLEM

SOLUTIONS

W

ATER

HE

ATER

Unit does not ignite

when water goes

through the unit

• Is the power on the water heater?

• Is the gas on?

• Is the flow rate over 05 GPM (19 L/min)? (p 37)

• Is the filter on cold water inlet clean? (p 41)

• Check for reverse connection and cross connection (p 22)

• If you use the remote controller and/or temperature controller, is

the power button turned on? (p 37 and 38)

• Check if the inlet temperature is too high

The fan motor is

still spinning after

operation has stopped

• This is normal After operation has stopped, the fan motor keeps

running from 15 to 70 seconds in order to re-ignite quickly, as well

as purge all the exhaust gas out of the flue

Abnormal sounds from

the water heater

• Is the correct gas type of a water heater installed? (p 6)

• Are the DIPswitch settings for your altitude set correctly? (p 28)

• Check the flame quality (p 41)

• Is the intake or exhaust vent blocked? (p 10)

• Is the vent length and diameter correct? (p 11 to 16)

• Is the manifold pressure set correctly? (p 4)

Unit sounds abnormal

while in operation

• Contact the manufacturer at 1-877-737-2840

Remot

e

con

tr

oller

Controller does not

display anything when

the power button is

turned on

• Make sure the water heater is supplied with power

• Make sure the connection to the water heater is correct (p 26 and

27)

NOTICE:

When the water heater has not operated for five minutes or more,

the display of the controllers turns off to conserve energy

An ERROR code is

displayed

• Please see p

45 to 47

When the remote

controller is turned

ON, STAND BY LED

is lit

Troubleshooting

Owner's Guide

Advertising