Disassembly Procedures

15

RS2320006 Rev. 0

To avoid risk of electrical shock, personal injury or death;

disconnect power supply source before servicing, unless

testing requires it.

WARNING

!

Storage Drawer Removal

1. Pull drawer out until it stops.

2. Grasp drawer sides near back of drawer and lift up

and out.

3. Reverse procedure to reinstall storage drawer.

Storage Drawer Tracks

1. Remove storage drawer from unit.

2. Remove bolt and nut securing track to the chassis

(located in the front of the unit).

3. Slide track backwards and then forward to remove

track.

Power Cord

1. Slide unit outward to gain access to power cord.

2. Unplug power cord from receptacle.

3. Remove screw securing power cord to unit chassis.

4. Disconnect power cord.

5. Reverse procedure to reassemble.
NOTE: Power cord NOT supplied with unit.

Removing and Replacing Range

1. Disconnect power to range.

2. Slide range forward on slide guards.
NOTE: Usage of slide guards, prevents the unit from

damaging the floor.

3. Unplug range cord and place range aside.

4. Remove anti-tip bracket.

5. Install anti-tip bracket into new location using

instructions provided with bracket.

6. To reinstall range, follow instructions in Installation

section of this manual.