Table 51 Troubleshooting Problems with the Status of Logical Paths (continued)

Corrective Action

Description

Path Status

Make sure that the topology settings of the local and
remote storage system ports are correct.

Make sure that you entered the correct remote storage
system S/N and path parameters (for example, local
storage system port, remote storage system port, and
controller ID). After that, delete the failed path. You
may need to change the minimum paths setting or
delete the remote storage system in order to delete the
path. After the deletion finishes, add the path and the
remote storage system again by using the Add Path
window and the Add DKC window.

The specified port is not
configured as an RCP or
initiator port, or this path
already exists.

Invalid Port

Delete the failed path. You may need to change the
minimum paths setting or delete the remote storage
system in order to delete the path. After the deletion
finishes, add the path and the remote storage system
again by using the Add Path window and the Add DKC
window.

This path was not established.

<blank>

Make sure that you specified the correct remote storage
system port. Correct the port number if necessary.

Make sure that the local storage system port and the
remote storage system port are connected via cables
to each other. If the storage systems are not connected
via cables, connect them via cables and then retry the
operation.

Make sure that the topology settings of ports on the
local and remote storage systems are correct.

The specified port in the
remote storage system is
physically disconnected from
the local storage system.

Pair-Port Number
Mismatch

Make sure that the specified port in the remote storage
system is configured as an RCU target port. Configure
the port as an RCU target port if it is not configured
that way.

The specified port in the
remote storage system is not
configured as an RCU Target
port.

Pair-Port Type
Mismatch

Make sure that the remote storage system port and
network relay devices (for example, cables and
switches) are properly configured and functioning.

The local storage system is
connected to the remote
storage system successfully,
but a logical communication
timeout occurred.

Communication
Failed.

Delete the error path.

Check the specified port number or cable connections,
and then retry the operation.

The specified port number is
not correct, or the cable is not
connected to the specified
port.

Port Number
Mismatch

Delete the failed path and retry.

A timeout error has occurred
in the fibre path between the
local and remote storage
systems.

Communication
Error

238 Troubleshooting