Power capping 43
A power cap can be set between the minimum cap value of 585 and the maximum cap value of 2372. In this
example, the cap applies only to the chassis located at APM Port 1, DM Port 2 because that is the only
chassis that met the necessary prerequisites for power capping. Under circumstances with many chassis, the
allowable cap range would fall between the total minimum and total maximum values.
Under normal circumstances, the average chassis power level might be up to 5% above the chassis power
cap. However, the cap value might vary under extreme power usage situations.
When running the baseline calibration, the target system (all nodes in chassis) has to be running at the
production level load.
The following is an example with mixed Power Management Controller (SL Chassis) Firmware version 4.3
and lower:
> show power
MDM Port Node Avg Min Max
---- ---- ---- ----- ----- -----
1 1 1
78 n/a 206 (DC watts)
1 1 2 80 n/a 203 (DC watts)
1 1 3 77 n/a 208 (DC watts)
1 1 4 77 n/a 206 (DC watts)
1 1 5 81 n/a 207 (DC watts)
1 1 6 76 n/a 210 (DC watts)
1 1 7 82 n/a 225 (DC watts)
1 1 8 81 n/a 225 (DC watts)
1 2 (no SL enclosure present)
1 3 1 255 n/a 337 (DC watts)
1 3 2 257 n/a 340 (DC watts)
1 3 3 242 n/a 324 (DC watts)
1 3 4 232 n/a 315 (DC watts)
1 3 5 265 n/a 351 (DC watts)
1 3 6 259 n/a 344 (DC watts)
1 3 7 240 n/a 325 (DC watts)
1 3 8 258 n/a 346 (DC watts)
1 3 Fans 20 (DC watts)
1 3 2036 (Chassis total - DC watts)
1 3 2151 (Chassis total - AC watts)
1 3 2247 (Chassis cap - AC
watts)
1 4 1 91 n/a 188 (DC watts)
1 4 2 (empty)
1 4 3 115 n/a 186 (DC watts)
1 4 4 (empty)
1 4 5 (empty)
1 4 6 (empty)
1 4 7 (empty)
1 4 8 (empty)
1 4 Fans 14 (DC watts)
1 4 221 (Chassis total - DC watts)
1 4 266 (Chassis total - AC watts)
1 4 852 (Chassis cap - AC
watts)
1 5 (no SL enclosure present)
1 6 (no SL enclosure present)
1 7 (no SL enclosure present)
1 8 (no SL enclosure present)
1 9 (no SL enclosure present)
1 10 (no SL enclosure present)