Power capping 51

1 10 (no SL enclosure present)

2 (no Dist. Module present)

3 (no Dist. Module present)

4 (no Dist. Module present)

5 (no Dist. Module present)

6 (no Dist. Module present)

7 (no Dist. Module present)

8 (no Dist. Module present)

----- ----- -----

400 0 1007 (Totals)

50 0 125 (Averages)


Total servers = 8

Total chassis = 2

Total fan wattage = 270 (DC watts)

Total system wattage = 670 (DC watts)

Total system wattage = 743 (AC watts)

PDM Port Load

---- ---- ----

1 (no PDM Extension present)

2 (no PDM Extension present)

----

0

Setting power

Power management enables you to turn on and off single or multiple nodes within the rack.
To turn an SL server node on or off, use the SET POWER command:
SET POWER {ON|OFF|ENABLE|DISABLE} {ALL | <PORT#> <DMPORT#> {<NODE#>|ALL}}
where:
ALL is used when the command applies to all nodes. You can also use ALL when the command applies to

all the server nodes in a particular SL server enclosure.
<PORT#> refers to the SL-APM, PDM1, or PDM2 port numbers.
<DMPORT#> refers to the SL-APM Distribution Module port number or the HP Intelligent Modular PDU

Extension Bar outlet number.
<NODE#> refers to the SL server node.
For example, to power on SL server node 3, enter:
SET POWER ON 2 4 3
To power off SL server node 3, enter:
SET POWER DISABLE 2 4 3
When you power on a particular SL server enclosure, you must include either the node number or ALL in the

command.
To power on the SL server nodes in the enclosure, enter:
SET POWER ON 2 4 ALL
To power on all nodes connecting to the chassis on all SL-APM Distribution Module ports, enter:
SET POWER ON ALL