Installing EMU Microcode

C–2 UltraSCSI RAID Enclosure

Prerequisites

The following items are required to upgrade the EMU microcode
using the EMU UART connector:

EMU microcode file (for example, FLSH_011.HEX)

PC

Communications program, such as PROCOMM PLUS

Compaq adapter cable, part number 17–04697–01, with the
following connectors:

— 9-pin RS232

— 8-pin RJ45

Preliminary Procedure

Complete the procedure in Table C–1 prior to starting the installation
procedure.

Table C–1 Preliminary Procedures

1.

Shut down the software for each controller and eject its personal
computer memory card industry association (PCMCIA) card.

2.

Connect the 9-pin RS232 connector to a PC COM port connector.

3.

Connect the 8-pin RJ45 connector to the master EMU center UART
connector.

4.

Configure the communications software parameters as follows:

Parameter

Value

Baud rate

38,400 Baud

Data bits

8

Parity

None

Stop bits

1

Protocol

Raw ASCII

CR/LR conversion

None

XON/XOFF

None

Connection

Direct (no modem)

Flow control

None

Advertising