I/o module and expansion cable error conditions, Expanding the ultrascsi bus – HP Array Controller HSG V8.7 Software User Manual

Page 105

Advertising
background image

Single-Ended I/O Module

UltraSCSI RAID Enclosure 5–3

I/O Module and Expansion Cable Error Conditions

Removal of an I/O module causes the EMU to report the following
error conditions to the controller:

Installation of different I/O modules

Loss of TERMPOWER

Either of these error conditions might cause the controller to cease
operation without implementing procedures to protect the data.

Before removing an I/O module or an expansion cable, completion of
the following procedures is mandatory to prevent inducing a
controller error condition:

1.

Clear the cache and shut down the array controller.

2.

Turn O

FF

the enclosure power.

Caution

Replacing an I/O module or an expansion cable without
first shutting down the controller can adversely affect data
integrity.

Expanding the UltraSCSI Bus

Each I/O module has an UltraSCSI single-ended bus expansion
integrated circuit that isolates the internal and external SCSI bus,
enhances SCSI signals, and allows the use of a longer UltraSCSI bus
cable.

Two 68-pin VHDCI receptacle connectors on the I/O module are the
connection points for expanding the SCSI buses between enclosures.
These connectors are wired in parallel and act as a trilink connector.

In an expansion configuration, Compaq recommends a maximum
cable length
of 2 m (6.6 ft) between enclosures.