Changing options for a data volume pair – HP StorageWorks XP Remote Web Console Software User Manual

Page 150

Advertising
background image

Refresh: Updates the pair status information.

Close: Closes the Detailed Information window.

Changing Options for a Data Volume Pair

The Change Pair Option window allows you to change options for a pair of data volumes.

To change the pair options, follow the procedure below. Only the administrator of the primary
storage system can perform the following operation. The administrator of the secondary storage
system cannot perform the following operation:

1.

Ensure that the XP Remote Web Console main window is in Modify mode.

For detailed information about how to do this, see the XP Remote Web Console user's guide.

2.

Ensure that the Pair Operation window is displayed.

3.

In the list, select and right-click the desired pair(s).

CAUTION:

You can only change options for pairs in Duplex, or Suspend, Hold, or Hlde

status. If you select a pair in another status, you cannot go on to the subsequent steps.

4.

From the pop-up menu, select Change Pair Option.

The Change Pair Option window appears (

“Change Pair Option Window” (page 150)

).

5.

In the Change Pair Option window, change pair options and select Set.

NOTE:

If two or more pairs are selected in the list, the drop-down list on the window may

display blank for option values. If you do not want to change the current option value for each
of the pairs, ensure that the drop-down list displays blank. If you select a value other than
blank from the drop-down list, the selected value will be set to each of the pairs.

6.

See the Preview list in the Pair Operation window to check the settings that you have made.

To modify a setting, select and right-click the setting and then select Modify.

To cancel a setting, select and right-click the setting and then select Cancel.

7.

Select Apply to apply the changes that you have made.

NOTE:

If an error occurs, the rightmost column of the Preview list displays the error code.

To view detailed information about the error, right-click the error code and then select Error
Detail. An error message appears and gives you detailed information about the error.

Figure 67 Change Pair Option Window

The Change Pair Option window displays the following items that can be configured:

Error Level: Allows you to specify the range used for splitting a pair when a failure occurs.

Group: If a failure occurs with a pair, all pairs in the mirror where the pair belongs will
be split.

Volume: If a failure occurs with a pair, only the pair will be split.

150

Performing URz Pair Operations

Advertising
This manual is related to the following products: