HP ProLiant SL165z G7 Server User Manual
Page 25
Using LO100 25
Time elapsed: 53 seconds.
Download Complete.
•
The reset command causes a target to cycle from enabled to disabled and then to enabled again.
•
The set command assigns a specific value to a property or group of properties. The standard syntax
for the set command is set property=new value.
•
The set command is used to change any changeable property. If the current directory does not
contain the property you want to change, you must specify the target of the property before entering
the property you want to change.
•
The start command causes the system1 target to power on.
•
The stop command causes the system1 target to power off.
•
The version command queries the version of the CLP implementation or other CLP elements. For
example:
•
/./map1/-> version
•
Version 1.00
•
/./map1/-> cd firmware
•
/./map1/firmware/-> version
•
Version 1.00
•
/./map1/firmware/-> show
•
/./map1/firmware
•
Targets
•
Properties
•
fwversion=0.59
•
Verbs
•
cd
•
version
•
exit
•
show
•
reset
•
load
•
help
•
/./map1/firmware/-> show fwversion
•
fwversion=0.59
•
/./map1/firmware/-> fwversion
•
Invalid command
/./map1/firmware/->