Troubleshooting

229

HA-Fabric Manager User Guide

Reference

The system reboots or is

unable to gather SNMP

information.

Multiple SNMP calls are being sent to a device that

can't handle the constant requests for information.
To resolve this issue, verify that the devices you are

discovering are not being discovered by another

appliance. Discovering devices using multiple

appliances may result in errors.

A report failed to generate

due to memory constraints.

Generate a fewer number of reports at one time.

Receiving error

“Compatibility between

<TARGET VERSION> and

<CURRENT VERSION> is

unknown. Do you want to

continue?”

Firmware files are included in the upgrade process,

but release rules are not. Since release rules are

required when sending another firmware version to

a switch, this error results. To fix this problem, add

the latest firmware file to the firmware library. This

also adds the new release rules and resolve the

problem.

Error occurs when trying to

delete a nickname.

Once assigned, a nickname cannot be deleted and

left blank.

Table 19: Miscellaneous Problems and Resolutions (Continued)