Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-11



Table C-1: Display Messages

continued

Message Type

Description Action

50 REDUNDANCY
FAILED OUT OF
MEMORY

Error While

either attempting

to enter redundant mode
or already operating in
redundant mode, one of
the array controllers
failed to allocate required
memory. Redundancy is
disabled at this time.

If the MSA500 system is
currently involved in host
I/O:

1.

Remove the standby

array controller.

2.

Wait 10 seconds.

3.

Reinsert the controller,

and be sure that it
seats fully in the
chassis.

If this action does not solve
the problem, wait until
downtime is available and
do the following:

1.

Power down the

MSA500 system.

2.

Remove both array

controllers.

3.

Reinstall both array

controllers, and be sure
that they seat fully in
the chassis.

If this action does not solve
the problem, contact HP
support.