HP StorageWorks 500 Modular Smart Array User Manual

Page 148

Advertising
background image

Troubleshooting

HP StorageWorks Modular Smart Array 500 System User Guide

D-15



9. On the INSTALL.NLM Available Disk Drives menu, select the previously failed

logical drive, which has now been repaired. The device information was recorded
in step 1. For example:

NWPA:

[V503-A2-D1:0] Compaq SMART-2 Slot 8 Disk 2 NFT

10. Select the Delete Partition menu option. INSTALL.NLM may display several

error messages. Since you will delete this partition, do not update any Volume
Definition Table
information. Continue until the partition has been deleted.

11. If INSTALL.NLM reports that it cannot delete the partition because another

process has locked it, load MONITOR.NLM and look at the System Resources
option to determine which NLM has locked the device. It may be
MONITOR.NLM, so you will need to unload MONITOR.NLM and any other
NLMs that have the partition locked. After you create the partition and volume
information, reload those NLMs.

12. Create the partition on the same logical drive.

13. Create and mount the volume.

14. Locate the recent backup media and restore the data to this server volume.

Advertising