When the system does not start – HP StorageWorks 500 Modular Smart Array User Manual

Page 135

Advertising
background image

Troubleshooting

D-2

HP StorageWorks Modular Smart Array 500 System User Guide



When the System Does Not Start

WARNING: A risk of personal injury exists from hazardous energy levels. The
installation of options and the routine maintenance and service of this product
must be performed by individuals who are knowledgeable about the
procedures, precautions, and hazards associated with equipment containing
hazardous energy circuits.

If the system does not start:

1. Be sure that the attached server and monitor are working properly.

2. Be sure that the system is plugged into working outlets.

3. Be sure that the power source is working properly:

a. Check the status using the system power LED. For the location and

explanation of the system power LED, refer to Chapter 1, “Component
Identification.”

b. Be sure that the Power On/Standby button was pressed firmly.

4. Be sure that the power supplies are working properly.

Check the status using the power supply/blower assembly LEDs. For the location
and explanation of these LEDs, refer to “Rear Panel LEDs” in Chapter 1,
“Component Identification.”

5. Restart the system. Refer to “System Power Down” in Chapter 2, “Installation

and Operation.”

IMPORTANT: If the system does not restart, proceed to “Diagnostic Steps” in this
appendix.

6. Check the system for the following normal power-up sequence to be sure that the

system meets the minimal hardware requirements and is powered up during
normal operations:

a. The front panel system power LED turns from off (standby/off ) to solid

green (on).

b. The blowers start up.

c. The 2-Port or 4-Port Shared Storage Module LED flashes green.