HP StorageWorks 500 Modular Smart Array User Manual

Page 97

Advertising
background image

Display Messages

HP StorageWorks Modular Smart Array 500 System User Guide

C-5



Table C-1: Display Messages

continued

Message Type

Description Action

43 REDUNDANCY
FAILED HARDWARE
FAILURE

Error While

either attempting

to enter redundant mode
or already operating in
redundant mode, one of
the array controllers
encountered a hardware
failure on the
communication channel
between the two array
controllers. Redundancy
is disabled at this time.

If the MSA500 system is
currently involved in host
I/O:

1.

Remove the standby

array controller.

2.

Wait 10 seconds.

3.

Reinstall the controller,

and be sure that it
seats fully in the
chassis.

If this action does not
resolve the problem, wait
until downtime is available
and do the following:

1.

Power down the

MSA500 system.

2.

Remove both array

controllers.

3.

Reinstall both array

controllers, and be sure
that they seat fully in
the chassis.

If this action does not
resolve the problem, contact
HP support.

continued

Advertising