192 Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems

NOTE:

This section assumes that the user is familiar with batch files and does not provide instructions for

writing or editing batch files. The macro commands and parameters listed in this section are the only

commands recognized by the TC390 scripting function.

CAUTION:

The user is responsible for testing the TC390 scripting function before running any TC390

scripts. If a TC390 script is run without prior testing and the script ends abnormally, data loss could occur.

Before testing a TC390 script, back up the data and vary the volumes offline. If the volumes must remain

online, back up the data and confirm that the target volume pair defined in the TC390 script is correct. The

results of a TC390 script can be confirmed by checking the latest TC390 pair status update (Last Updated

box on TC390 Pair Status window).

Table 50

on page 192 lists the TC390 pair macro commands.

Table 51

on page 193 lists the internal

macro commands for TC390 scripting. The following TC390 operations cannot be performed using TC390

scripting:

Configure serial/fibre ports (”

Configuring the host interface ports

” on page 83).

Monitor remote copy activity (”

Usage Monitor window

” on page 77).

Clear remote copy SIMs (”

Other operations

” on page 113).

Add/delete RCU (”

Registering an RCU (Add RCU)

” on page 87 and

Deleting an RCU (Delete RCU)

on page 97).

Change RCU options (”

Modifying RCU options (Change RCU option)

” on page 92).

Add/delete path/SSID (”

Adding and deleting logical paths for an RCU (Add Path and Delete Path)

” on

page 97 and

Adding and deleting SSIDs for an RCU (Add SSID and Delete SSID)

” on page 100).

View RCU status (

Viewing RCU Status (RCU Status)

” on page 85).

Change async options (”

Asynchronous copy option

” on page 108).

Add/delete group (”

Adding consistency groups (Add CT Group)

” on page 105 and

Deleting

consistency groups (Delete CT Group)

” on page 107).

Change group options (

Modifying consistency group options (CT Group Option)

” on page 106).

View group status (”

Viewing consistency group status (CT Group Status)

” on page 103).

NOTE:

The scripting command names did not change between XP Continuous Access and TC390. Your

existing XP Continuous Access scripting files can be used for TC390 operations.

Table 50

Functional macro commands for TrueCopy scripting

TC390 Scripting Macro Description

CreateHrcPair

Registers a TC390 pair or pairs. (StartHrcPair is used to start the initial copy

operation.)

SuspendHrcPair

Suspends a TC390 pair or pairs.

DeleteHrcPair

Deletes a TC390 pair or TC390 pairs.

ResumeHrcPair

Resumes a TC390 pair or TC390 pairs. Use with StartHrcPair.

ChangeHrcOption

Changes the pair options for a TC390 pair or TC390 pairs.

StartHrcPair

Starts remote copy operations for the new pairs and/or resumed pairs specified in

the preceding scripting commands.

GetHrcStatus

Displays the status of a TC390 pair or TC390 pairs.

SelectHrcDevice

Searches TC390 paired devices.

Advertising