HP Hitachi Dynamic Link Manager Software User Manual

Page 32

Advertising
background image

For details on error levels, see

Table 8-1 Format and Meaning of the Message

ID KAPLnnnnn-l on page 8-2

in

Format and Meaning of Message IDs on

page 8-2

..

When the Hitachi AMS/WMS series is being used, HDLM will select the path to

be used next from among the various paths that access the same LU, starting

with owner paths, and then non-owner paths.

For example, in

Figure 2-10 Path Switching on page 2-15

, the owner

controller of an LU is CHA0, and access to the LU is made via only one path

(A). After that access path (A) is placed offline, the first choice for the

switching destination is the other path connected to CHA0 (B). If an error

also occurs on that path (B), then the next possibility for a path comes from

one of the two paths (C or D) connected to CHA1.

When the Universal Storage Platform V/VM series, Virtual Storage Platform
series, Hitachi AMS2000 series

#

, Hitachi SMS series

#

, HUS100 series

#

, or

HUS VM is being used, all the paths are owner paths. This means that all the

paths that are accessing the same LU are possible switching destinations. For

example, in

Figure 2-10 Path Switching on page 2-15

, the LU is accessed

using only the one path (A). However, after that path is placed offline, the

switching destination can come from any of the other three paths (B, C, or

D).

#

This storage system applies when the dynamic I/O path control function is

disabled.

2-14

HDLM Functions

Hitachi Dynamic Link Manager User Guide for VMware

®

Advertising
This manual is related to the following products: