Table 34 MPX200 log messages (continued)

Unable to create an object for the
target node; exceeded the maximum
number of target devices.

Error

App

QLBA_CreateTargetNodeObject:

Too many devices

41060

Memory unavailable for LUN object.

Error

App

QLBA_CreateLunObject: LunObject

memory unavailable

41067

Unable to create an object for initiator
object; exceeded the maximum
number of initiators.

Error

App

QLBA_CreateInitiatorObject: Too

many initiators

41077

Process control block status indicates
that a PCI error occurred during a
target operation.

Error

App

QLBA_DisplayTargetOperationStatus:

PCI Error, Status 0x%.2x

41096

Process control block status indicates
that a DMA error occurred during an
initiator operation.

Error

App

QLBA_DisplayInitiatorOperationStatus:

DMA Error, Status 0x%.2x

41106

Process control block status indicates
that a transport error (protocol)
occurred during an initiator operation.

Error

App

QLBA_DisplayInitiatorOperationStatus:

Transport Error, Status 0x%.2x

41107

Process control block status indicates
that a data overrun error occurred
during an initiator operation.

Error

App

QLBA_DisplayInitiatorOperationStatus:

Data Overrun, Status 0x%.2x

41111

iSCSI login failed between receipt of
PDU and request for the data segment.

Error

App

QLIS_LoginPduContinue:

Operation failed. Initiator

0x%x, TPB status 0x%x

41234

iSCSI login failed due to unsupported
version number in received login PDU.

Error

App

QLKV_ValidateLoginTransitCsgNsgVersion

failed (status 0x%x)

41238

iSCSI login PDU contains invalid
initiator name. The format and

Error

App

QLIS_LoginPduContinue: Invalid

initiator name. Initiator:

41257

character set used to form the initiator
name is invalid.

iSCSI target login was attempted to a
portal (iSCSI1 or iSCSI2) on which the
target is not presented.

Error

App

QLIS_LoginPduContinue: Target

not configured for Portal

41265

iSCSI login PDU received for a target
with a target name unknown to the
router.

Error

App

QLIS_LoginPduContinue: Target

not found. Target name:

41267

iSCSI login PDU received without a
target name for a normal session.

Error

App

QLIS_LoginPduContinue: Missing

target name

41268

iSCSI login PDU received without an
initiator name key/value.

Error

App

QLIS_LoginPduContinue: TSIH is

0 but InitiatorName key/value

not provided

41270

iSCSI login PDU received with an
incorrect initiator task tag for a session

Error

App

QLIS_LoginPduContinue:

CONN_STATE_IN_LOGIN, Unknown

InitTaskTag

41272

which is partially logged in. This
would occur if a login PDU other than
the initial login PDU used an initiator
task tag which was different than the
initiator task tag provided in the initial
login PDU.

iSCSI login PDU was received with a
TSIH out of range. This would occur if

Error

App

QLIS_LoginPduContinue: TSIH

0x%x out of range

41283

the iSCSI initiator attempting the login
failed to used the TSIH value provided
in the Target Login Response PDU

217