HP Smart Update Manager User Manual

Page 86

Advertising
background image

Description

Parameter

These components are only installed by default on Gen8 and later servers.
This parameter does not apply to HP Integrity servers.

Possible values:

YES

, NO

This is a filter switch that allows you to view only the firmware components
required for installation.

ROMONLY

Do not use the /romonly parameter with the /softwareonly parameter.

Possible values:

YES

, NO

This is a filter switch that allows you to view only the software components
required for installation.

SOFTWAREONLY

Do not use the /softwareonly parameter with the /romonly parameter.

Possible values:

YES

, NO

Enables the credentials of the local host to be used as the credentials to
access the nodes instead of providing the user name and password
explicitly for each node.

USECURRENTCREDENTIAL

The assumption is that the current credentials are valid for the nodes that
are being accessed. (Applies to Windows only.)

Possible values:

YES

, NO

Instructs HP SUM to delete the input file after it has been read.

DELETEINPUTFILE

Possible values:

YES

, NO (default)

This parameter instructs HP SUM how to proceed when a component has
a failed dependency.

ONFAILEDDEPENDENCY

The default of OmitHost causes the host to be put in a failure state, and
no installation is attempted on it.

OmitComponent

clears the affected components and proceeds with any

updates that do not have dependency failures. Force attempts all updates,
even if they have dependency failures.

Possible values:

OmitHost

(default), OmitComponent, Force

This parameter is the IP address or the DNS name of a remote server,
remote iLO NIC port, Virtual Connect Ethernet or Fibre Channel Module
for c-Class BladeSystem, or BladeSystem OA.

HOST

When two OAs are in an enclosure, this parameter is the active OA. When
specifying the IP address, you can use either the IPv4 or IPv6 format.

This parameter specifies an already defined group name in the HP SUM
GUI.

Possible values:

IP address, DNS name

This parameter is the IP address or the DNS name of a remote server,
remote iLO NIC port, Virtual Connect Ethernet or Fibre Channel Module
for c-Class BladeSystem, or BladeSystem OA.

NODE

When two OAs are in an enclosure, this parameter is the active OA. When
specifying the IP address, you can use either the IPv4 or IPv6 format.

This parameter specifies an already defined group name in the HP SUM
GUI.

86

Using legacy scripts to deploy updates

Advertising