HP StorageWorks XP Remote Web Console Software User Manual

Page 33

Advertising
background image

Flex Copy XP user guide

33

• Configuration definition file for S-VOL A:

Examples for the Head Office
The following are examples of the configuration definition file that should be prepared in Server B.

Again, you must check the connection configuration using the

raidscan

command first. However,

because P-VOL B is a mapped internal LU by an external LU, you must add the

-fe

option to the

raidscan

command to confirm that the volume is actually in the external array. After checking the

connection configuration, you can create the configuration definition files to operate the Flex Copy XP

pair, which consists of P-VOL B and S-VOL B.
• Checking the connection configuration from Server B:

• Configuration definition file for P-VOL B:

HORCM_MON

#ip_address service poll(10ms) timeout(10ms)

127.0.0.1 52051 1000 3000

HORCM_CMD

#dev_name dev_name dev_name

/dev/rdsk/c1t0d2

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

si-pairs dev1 CL1-B 2 1 0

HORCM_INST

#dev_group ip_address service

si-pairs 127.0.0.1 52050

# raidscan -p cl1-c -fe -CLI

PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Status Fence E-Seq# E-LDEV#

CL1-C e4 0 3 1 30053 1 16 SMPL - - 62468 257

# raidscan -p cl1-d -CLI

PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Status Fence P-Seq# P-LDEV#

CL1-D e2 0 4 1 30053 1 17 SMPL - - - -

HORCM_MON

#ip_address service poll(10ms) timeout(10ms)

127.0.0.1 52050 1000 3000

HORCM_CMD

#dev_name dev_name dev_name

/dev/rdsk/c1t0d2

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

hicp-pairs dev1 CL1-C 3 1 0

HORCM_INST

#dev_group ip_address service

hicp-pairs 127.0.0.1 52051

Advertising